Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20.568
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Se Pu ; 42(5): 481-486, 2024 Apr 08.
Artigo em Chinês | MEDLINE | ID: mdl-38736392

RESUMO

Ibandronate sodium, a third-generation diphosphate drug used worldwide to treat osteoporosis, has the advantages of convenient use, low toxicity, and significant therapeutic effects. However, the residual organic solvents in the synthesis process of sodium ibandronate not only have a negative impact on the efficacy of the drug, but also lead to a decrease in drug stability. Moreover, if the residual amounts of these solvents exceed safety standards, they may pose serious threats to human health. This study successfully established a convenient and efficient method based on headspace-gas chromatography (HS-GC) for the simultaneous determination of five residual solvents (methanol, acetone, benzene, toluene, 1-pentanol) in the raw materials of ibandronate sodium. The results indicated that satisfactory analytical performance can be achieved by using DB-624 capillary column (30 m×0.32 mm×1.8 µm) and a flame ionization detector in conjunction with headspace autosampling and a temperature program. The specific operating conditions included an initial temperature of 40 ℃, with a hold of 2 min, followed by a temperature ramp first to 200 ℃ at a rate of 5 ℃/min and then to 240 ℃ at a rate of 20 ℃/min, with a hold of 5 min. Nitrogen with a flow rate of 1 mL/min and split ratio of 14∶1 was used as the carrier gas. The headspace vial temperature was maintained at 80 ℃, and the sample equilibration time was 20 min. Under the established analytical conditions, good linear relationships were obtained between the mass concentrations of methanol (72-216 µg/mL), acetone (120-360 µg/mL), benzene (0.048-0.144 µg/mL), toluene (21.36-64.08 µg/mL), and 1-pentanol (120-360 µg/mL) and their corresponding peak areas, with correlation coefficients (r) greater than 0.990. The limits of detection for these solvents were 2.88, 0.011, 0.90, 0.24, and 0.024 ng/mL, respectively, with limits of quantification of 11.5, 0.043, 3.6, 0.96, and 0.096 ng/mL, respectively. Furthermore, the recoveries of these solvents ranged from 86.3% to 101.9%, with relative standard deviations (RSDs, n=3) of less than 2.49%. The proposed method is simple, accurate, reliable, and suitable for the rapid and simultaneous determination of five residual solvents in the raw materials of ibandronate sodium. This study has important practical significance in improving drug safety and ensuring public health.


Assuntos
Ácido Ibandrônico , Solventes , Cromatografia Gasosa/métodos , Solventes/química , Ácido Ibandrônico/análise , Difosfonatos/análise , Contaminação de Medicamentos
2.
Chirality ; 36(5): e23676, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38736271

RESUMO

Among different substance classes, New Psychoactive Substances (NPS) comprise chiral amphetamines for stimulant and empathic effects. There is little knowledge in terms of clinical studies about possibly different effects of the two enantiomers of novel amphetamine derivatives. For this reason, there is a big demand for enantioseparation method development of this new substance class. Regarding gas chromatography, cyclodextrins proved to be effective for enantioseparation of NPS. In our attempt, an Astec® Chiraldex™ G-PN column containing 2,6-di-O-pentyl-3-propionyl-γ-cyclodextrin and a Lipodex™ D column containing heptakis-(2,6-di-O-pentyl-O-acetyl)-ß-cyclodextrin as chiral selector served as stationary phases in a Shimadzu GCMS-QP2010 SE system. Because of the special coating, maximum temperature is limited to 200 °C isothermal or 220 °C in programmed mode. To ensure detection, trifluoroacetic anhydride (TFAA) was used to increase sample volatility.1 As a result, 35 amphetamines were tested as their TFAA-derivatives. A screening method with a temperature gradient from 140 °C to 200 °C at a heating ramp of 1 °C per minute and final time of 5 min, showed baseline separation for seven and partial separations for 16 trifluoro acetylated amphetamines using the Chiraldex™ G-PN column. Six baseline and nine partial separations were observed with the Lipodex™ D column, respectively.


Assuntos
Anfetaminas , Estereoisomerismo , Anfetaminas/química , Anfetaminas/isolamento & purificação , Cromatografia Gasosa/métodos , Ciclodextrinas/química , Temperatura , Cromatografia Gasosa-Espectrometria de Massas/métodos
3.
J Chromatogr A ; 1725: 464949, 2024 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-38688054

RESUMO

This study introduces an innovative needle trap device (NTD) featuring a molecularly imprinted polymer (MIP) surface-modified Zeolite Y. The developed NTD was integrated with gas chromatography-flame ionization detector (GC-FID) and employed for analysis of fuel ether oxygenates (methyl tert­butyl ether, MTBE, ethyl tert­butyl ether, ETBE, and tert­butyl formate, TBF) in urine samples. To optimize the key experimental variables including extraction temperature, extraction time, salt concentration, and stirring speed, a central composite design-response surface methodology (CCD-RSM) was employed. The optimal values for extraction in the study were found to be 51.2 °C extraction temperature, 46.2 min extraction time, 27 % salt concentration, and 620 rpm stirring speed. Under the optimized conditions, the calibration curves demonstrated excellent linearity within the range of 0.1-100 µg L-1, with correlation coefficients (R2) exceeding 0.99. The limits of detection (LODs) for MTBE, ETBE, and TBF were obtained 0.06, 0.08, and 0.09 µg L-1, respectively. Moreover, the limits of quantification (LOQs) for MTBE, ETBE, and TBF were obtained 0.18, 0.24, and 0.27 µg L-1, respectively. The enrichment factor was also found to be in the range of 98-129.The NTD-GC-FID procedure demonstrated a high extraction efficiency, making it a promising tool for urinary biomonitoring of fuel ether oxygenates with improved sensitivity and selectivity compared to current methods.


Assuntos
Limite de Detecção , Éteres Metílicos , Zeolitas , Zeolitas/química , Humanos , Éteres Metílicos/urina , Éteres Metílicos/química , Polímeros Molecularmente Impressos/química , Monitoramento Biológico/métodos , Cromatografia Gasosa/métodos , Etil-Éteres/urina , Etil-Éteres/química
4.
Environ Geochem Health ; 46(5): 161, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38592512

RESUMO

Hexavalent chromium (Cr (VI)) is an environmental contaminant brining high concerns due to its higher toxicity and mobility in comparison with trivalent chromium Cr(III). Cr (VI) has been linked with several adverse health effects, including respiratory diseases, lung cancer, and skin irritation. The primary sources of it in the environment are industrial activities.Most of the time, fly ash made of lignite can release Cr(VI) when it comes into contact with water in an aquatic environment. The objective of this study is the investigation of Cr (VI) concentration in leachates of fly ash and marl mixtures and the determination of its solubility under different pH conditions. Samples of fly ash were collected from the Power Plant of Agios Dimitrios. Additionally, samples of marl were collected from the mine of South Field, and both samples were mixed and prepared in in different proportions (% w.t.). The leaching experiments were carried out according to the EN-12457/1-4 (2003) standard under different pH conditions and chemical analysis of the leachates were performed by spectrophotometry with diphenylcarbazide (DPC). The environmental footprint of Cr (VI) in the study area was significant, especially in mixtures containing higher concentrations of fly ash. A critical pH range between 6 to 12 is observed. At acidic pH values, a high release of Cr (VI) was observed, while at the mentioned critical values (pH 10-12), a gradual decrease in its leachability was noticed. The high concentrations of Cr (VI) in the industrial area studied require immediate actions in terms of managing and limiting the potential hazardous impacts on the environment and by extension on the public health by developing appropriate prevention strategies.


Assuntos
Cromo , Cinza de Carvão , Humanos , Grécia , Cromo/toxicidade , Cromatografia Gasosa
5.
Int J Mol Sci ; 25(7)2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38612781

RESUMO

Poplars provide medicinal raw plant materials used in pharmacy. Leaf buds are one of the herbal medicinal products collected from poplars, having anti-inflammatory and antiseptic properties, but there are no quality standards for their production and there is a need to determine their botanical sources. Therefore, the chemical compositions of the leaf buds from four species and varieties of poplars, Populus balsamifera, P. × berolinensis, P. × canadensis 'Marilandica', and P. wilsonii were investigated and compared using gas chromatography coupled with mass detection (GC-MS) and two-dimensional high-performance thin-layer chromatography (2D-HPTLC) in order to search for taxa characterized by a high content of biologically active compounds and with a diverse chemical composition that determines their therapeutic effects. The presence of 163 compounds belonging to the groups of flavonoids, phenolic acids derivatives, glycerides, and sesquiterpenes was revealed. Moreover, the conditions for the separation and identification of biologically active compounds occurring in analyzed leaf buds using 2D-HPTLC were optimized and used for metabolomic profiling of the studied poplars, enabling their fast and simple botanical identification. The total phenolic (TPC) and flavonoid (TFC) contents of examined extracts were determined and their antioxidant capacities were estimated by spectrophotometric DPPH, ABTS, and FRAP assays. Based on the analysis of phytochemicals and antioxidant activity, P. × berolinensis buds were selected as the raw plant material for medicinal purposes with the highest content of active compounds and the strongest antioxidant activity.


Assuntos
Antioxidantes , Populus , Cromatografia em Camada Fina , Cromatografia Gasosa , Flavonoides , Folhas de Planta
6.
J Chromatogr A ; 1722: 464869, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38604057

RESUMO

Hydrodynamics, efficiency, and loading capacity of two semi-packed columns with different cross sections (NANO 315 µm x 18 µm; CAP 1000 µm x 28 µm) and similar pillar diameter and pillar-pillar distance (respectively 5 µm and 2.5 µm) have been compared in high-pressure gas chromatography. A flow prediction tool has been first designed to determine pressure variations and hold-up time across the chromatographic system taking into account the rectangular geometry of the ducts into the semi-packed columns. Intrinsic values of Height Equivalent to Theoretical Plate were determined for NANO and CAP columns using helium as carrier gas and similar values have been obtained (30 µm) for the two columns. Loading capacity of semi-packed columns were determined for decane at 70 °C using helium, and the highest value was obtained from CAP column (larger cross section and stationary phase content). Finally, significant HETP improvement (down to 15 µm) and peak shape were observed when carbon dioxide was used as carrier gas, suggesting mobile phase adsorption on stationary phase in high pressure conditions.


Assuntos
Hélio , Pressão , Cromatografia Gasosa/métodos , Cromatografia Gasosa/instrumentação , Hélio/química , Hidrodinâmica , Dióxido de Carbono/química , Adsorção
7.
J Pharm Biomed Anal ; 244: 116128, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-38598924

RESUMO

Genotoxic impurities (GTIs) are potential carcinogens that need to be controlled down to ppm or lower concentration levels in pharmaceuticals under strict regulations. The static headspace gas chromatography (HS-GC) coupled with electron capture detection (ECD) is an effective approach to monitor halogenated and nitroaromatic genotoxins. Deep eutectic solvents (DESs) possess tunable physico-chemical properties and low vapor pressure for HS-GC methods. In this study, zwitterionic and non-ionic DESs have been used for the first time to develop and validate a sensitive analytical method for the analysis of 24 genotoxins at sub-ppm concentrations. Compared to non-ionic diluents, zwitterionic DESs produced exceptional analytical performance and the betaine : 7 (1,4- butane diol) DES outperformed the betaine : 5 (1,4-butane diol) DES. Limits of detection (LOD) down to the 5-ppb concentration level were achieved in DESs. Wide linear ranges spanning over 5 orders of magnitude (0.005-100 µg g-1) were obtained for most analytes with exceptional sensitivities and high precision. The method accuracy and precision were validated using 3 commercially available drug substances and excellent recoveries were obtained. This study broadens the applicability of HS-GC in the determination of less volatile GTIs by establishing DESs as viable diluent substitutes for organic solvents in routine pharmaceutical analysis.


Assuntos
Solventes Eutéticos Profundos , Contaminação de Medicamentos , Limite de Detecção , Mutagênicos , Contaminação de Medicamentos/prevenção & controle , Cromatografia Gasosa/métodos , Mutagênicos/análise , Preparações Farmacêuticas/análise , Preparações Farmacêuticas/química , Solventes Eutéticos Profundos/química , Solventes Eutéticos Profundos/análise , Química Verde/métodos , Reprodutibilidade dos Testes , Solventes/química
8.
J Agric Food Chem ; 72(17): 9523-9554, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38640191

RESUMO

Gas chromatography-olfactometry (GC-O) has made significant advancements in recent years, with breakthroughs in its applications and the identification of its limitations. This technology is widely used for analyzing complex odor patterns. The review begins by explaining the principles of GC-O, including sample preparation, separation methods, and olfactory evaluation techniques. It then explores the diverse range of applications where GC-O has found success, such as food and beverage industries, environmental monitoring, perfume and aroma development, and forensic analysis. One of the major breakthroughs in GC-O analysis is the improvement in separation power and resolution of odorants. Techniques like rapid GC, comprehensive two-dimensional GC, and multidimensional GC have enhanced the identification and quantification of odor-active chemicals. However, GC-O also has limitations. These include the challenges in detecting and quantifying trace odorants, dealing with matrix effects, and ensuring the repeatability and consistency of results across laboratories. The review examines these limitations closely and discusses potential solutions and future directions for improvement in GC-O analysis. Overall, this review presents a comprehensive overview of the recent advances in GC-O, covering breakthroughs, applications, and limitations. It aims to promote the wider usage of GC-O analysis in odor analysis and related industries. Researchers, practitioners, and anyone interested in leveraging the capabilities of GC-O in analyzing complex odor patterns will find this review a valuable resource. The article highlights the potential of GC-O and encourages further research and development in the field.


Assuntos
Odorantes , Olfatometria , Odorantes/análise , Olfatometria/métodos , Cromatografia Gasosa/métodos , Cromatografia Gasosa/instrumentação , Humanos , Olfato , Compostos Orgânicos Voláteis/análise , Compostos Orgânicos Voláteis/química
9.
Molecules ; 29(7)2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38611821

RESUMO

This study aimed to investigate the volatile flavor compounds and tastes of six kinds of sauced pork from the southwest and eastern coastal areas of China using gas chromatography-ion mobility spectroscopy (GC-IMS) combined with an electronic nose (E-nose) and electronic tongue (E-tongue). The results showed that the combined use of the E-nose and E-tongue could effectively identify different kinds of sauced pork. A total of 52 volatile flavor compounds were identified, with aldehydes being the main flavor compounds in sauced pork. The relative odor activity value (ROAV) showed that seven key volatile compounds, including 2-methylbutanal, 2-ethyl-3, 5-dimethylpyrazine, 3-octanone, ethyl 3-methylbutanoate, dimethyl disulfide, 2,3-butanedione, and heptane, contributed the most to the flavor of sauced pork (ROAV ≥1). Multivariate data analysis showed that 13 volatile compounds with the variable importance in projection (VIP) values > 1 could be used as flavor markers to distinguish six kinds of sauced pork. Pearson correlation analysis revealed a significant link between the E-nose sensor and alcohols, aldehydes, terpenes, esters, and hetero-cycle compounds. The results of the current study provide insights into the volatile flavor compounds and tastes of sauced pork. Additionally, intelligent sensory technologies can be a promising tool for discriminating different types of sauced pork.


Assuntos
Carne de Porco , Carne Vermelha , Suínos , Animais , Nariz Eletrônico , China , Análise Espectral , Aldeídos , Cromatografia Gasosa
10.
Se Pu ; 42(4): 387-392, 2024 Apr.
Artigo em Chinês | MEDLINE | ID: mdl-38566428

RESUMO

The residual amount of halogenated solvents in olive oil is an important indicator of its quality. The National Olive Oil Quality Standard GB/T 23347-2021 states that the residual amount of individual halogenated solvents in olive oil should be ≤0.1 mg/kg and that the total residual amount of halogenated solvents should be ≤0.2 mg/kg. COI/T.20/Doc. No. 8-1990, which was published by the International Olive Council, describes the standard method used for the determination of halogenated solvents in olive oil. Unfortunately, this method is cumbersome, has poor repeatability and low automation, and is unsuitable for the detection and analysis of residual halogenated solvents in large quantities of olive oil. At present, no national standard method for determining residual halogenated solvents in olive oil is available in China. Thus, developing simple, efficient, accurate, and stable methods for the determination of residual halogenated solvents in olive oil is imperative. In this paper, a method based on automatic headspace gas chromatography was established for the determination of residual halogenated solvents, namely, chloroform, carbon tetrachloride, 1,1,1-trichloroethane, dibromochloromethane, tetrachloroethylene, and bromoform, in olive oil. The samples were processed as follows. After mixing, 2.00 g (accurate to 0.01 g) of the olive oil sample was added into a 20 mL headspace injection bottle and immediately sealed for headspace gas chromatography analysis. Blank virgin olive oil was used to prepare a standard working solution and the external standard method for quantification. The solvents used in the preparation of halogenated solvent standard intermediates were investigated and methanol was selected as a replacement for N,N-dimethylacetamide to prepare a halogenated solvent standard intermediate owing to its safety. The effects of different injection times (1, 2, 3, 4, 5, 6 s), equilibration temperatures (60, 70, 80, 90, 100, 110, 120 ℃), and equilibration times (4, 5, 8, 10, 20, 30, 40 min) of the headspace sampler on the detection of the residual amounts of the six halogenated solvents were investigated. The optimal injection time and equilibration temperature were 3 s and 90 ℃, respectively. The method demonstrated good analytical performance for the six halogenated solvents when the equilibration time was 30 min. A methodological study was conducted on the optimized method, and the results showed that the six halogenated solvents exhibited good linear relationships in the range of 0.002-0.200 mg/kg, with correlation coefficients of ≥0.9991. The limits of detection (LODs) and quantification (LOQs) of 1,1,1-trichloroethane and bromoform were 0.0006 and 0.002 mg/kg, respectively. The LODs and LOQs of chloroform, carbon tetrachloride, dibromochloromethane, and tetrachloroethylene were 0.0003 and 0.001 mg/kg, respectively. The average recoveries under different spiked levels were 85.53%-115.93%, and the relative standard deviations (n=6) were 1.11%-8.48%. The established method was used to analyze 13 olive oil samples available in the market. Although no halogenated solvents were detected in these samples, a limited number of samples does not represent all olive oils. Hence, monitoring residual halogenated solvents in olive oil remains necessary for its safe consumption. The LOQs of the method for the six halogenated solvents were significantly lower than that of the COI/T.20/Doc. No. 8-1990 standard method (0.02 mg/kg). In addition, the developed method can be conducted under short operation times with high precision and degree of automation as well as good accuracy. Thus, the proposed method is suitable for the determination and analysis of the residues of the six halogenated solvents in large batches of olive oil samples.


Assuntos
Tetracloroetileno , Tricloroetanos , Azeite de Oliva , Solventes/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos , Tetracloroetileno/análise , Clorofórmio/análise , Tetracloreto de Carbono/análise , Cromatografia Gasosa/métodos , Trialometanos
11.
Methods Mol Biol ; 2789: 75-83, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38506993

RESUMO

Various organic solvents are widely used in the manufacturing, processing, and purification of drug substances, drug products, formulations, excipients, etc. These solvents must be removed to the lowest amount permitted, as they do not possess any therapeutic advantages and may cause undesirable toxicities. Therefore, a rapid and sensitive analytical method for the quantitation of residual solvents is needed. The following chapter presents a static headspace gas chromatographic (HSGC) method for determining the concentration of common residual solvents in various nanoformulations. An efficient and sensitive HSGC method has been developed using PerkinElmer's headspace autosampler/gas chromatographic system with a flame ionization detector (FID) and validated according to the International Conference for Harmonization (ICH) guideline Q3C. The method validation indicates that the method is specific, linear, accurate, precise, and sensitive for the analyzed solvents. The method is suitable for the analysis of 13 residual solvents (methanol, ethanol, acetone, diethyl ether, 2-propanol, acetonitrile, 1-propanol, ethyl acetate, tetrahydrofuran, dichloromethane, chloroform, 1-butanol, and pyridine) and utilizes an Elite 624 Crossbond 6% cyanopropylphenyl, 94% dimethylpolysiloxanes column with helium as a carrier gas.


Assuntos
Etanol , Metanol , Cromatografia Gasosa/métodos , Solventes/química , Ionização de Chama , Metanol/análise
12.
Artigo em Inglês | MEDLINE | ID: mdl-38460448

RESUMO

This work reports the characterization of the lipidic fraction of seven species of marine organisms gathered along the shoreline of the Po Delta Park of Emilia-Romagna Region (Italy) and of the north Adriatic Sea. Two species of oysters (Crassostrea gigas and Ostrea edulis), two species of clams (Chamelea gallina and Ruditapes philippinarum), one species of mussel (Mytilus galloprovincialis), one species of macroalgae (Ulva rigida), and one species of spiny dogfish (Squalus acanthias) were analyzed to characterize their fatty acids profile and related nutritional value. The lipid fraction was simultaneously extracted and transesterified into fatty acid methyl esters (FAMEs) by using a recently developed one-step microwave-assisted extraction/derivatization (MAED) method. The obtained FAMEs extract was analyzed by a rapid comprehensive multidimensional gas chromatography (GC × GC) method (30 min). The system was equipped with a reverse set of columns (polar × non-polar) connected through a reversed fill/flush flow modulator. The GC × GC system was coupled with a flame-ionization detector (FID) for both qualitative and quantitative purposes. The MAED- GC × GC-FID methodology was suitable in the context of samples containing high percentages of omega-3 PUFA. A total of 82 FAMEs were tentatively identified using standards, literature data, and the two-dimensional plot location. FAME profiles obtained with the proposed approach were comparable with reference methods (AOCS Ce 2b-11), showing no significant differences. Moreover, to determine the food nutritional value of the samples investigated, the most common nutritional indices (index of atherogenicity, index thrombogenicity, hypocholesterolemic/hypercholesterolemic ratio, health-promoting index, unsaturation index, and the fish lipid quality index) were calculated from FAME profiles. Among the samples investigated, Squalus acanthias presented the best nutritional score, while Ruditapes philippinarum had the worst score in 3 out of 6 indices.


Assuntos
Organismos Aquáticos , Algas Comestíveis , Ácidos Graxos , Ulva , Animais , Ácidos Graxos/análise , Ionização de Chama/métodos , Micro-Ondas , Cromatografia Gasosa/métodos
13.
Artigo em Chinês | MEDLINE | ID: mdl-38538245

RESUMO

As a rapid, accurate and efficient analytical technique, gas chromatography is widely used in the detection of volatile organic compounds and inorganic small molecule toxins, and it is the main analytical method in the national testing standards for occupational health. The existing effective national standards of gas chromatography for the detection of some substances have low column efficiency, high toxicity of reagents, poor correlation of the standard curve and low desorption efficiency and other problems, some of which can be solved through method improvement. At the same time, with the use of new materials and new processes, new types of toxic substances are emerging, and there are still many occupational disease hazards of limited value without supporting detection methods, gas chromatography can be applied to the detection of some toxic substances to better complement the vacancy of China's occupational health detection methods. This paper analyzes the current situation of the application of gas chromatography in occupational health testing standards, discusses the improvement of some of these methods, and helps to promote the application and development of gas chromatography in occupational health testing.


Assuntos
Poluentes Ocupacionais do Ar , Saúde Ocupacional , Poluentes Ocupacionais do Ar/análise , Local de Trabalho , Cromatografia Gasosa/métodos , China
14.
J Chromatogr A ; 1720: 464764, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38458137

RESUMO

The limit of detection (LOD) is a crucial measure in analytical methods, representing the smallest amount of a substance that can be distinguished from background noise. In the realm of gas chromatography (GC), however, determining LOD can be quite subjective, leading to significant variability among researchers. In this study, we validate the Hubaux-Vos method, an International Standards Organization(ISO)-approved approach for determining LOD in gas concentration measurements, using a GC equipped with a discharge ionization detector (DID) and a dynamic dilution system. We employ a gas mixture certified reference material (CRM) of CO, CH4, and CO2 at various concentrations to generate calibration curves for each gas. Subsequently, we estimate the LODs for each gas using the Hubaux-Vos method. Surprisingly, our findings indicate a notable difference between the LODs calculated using the Hubaux-Vos method and those confirmed through experiments. This highlights the importance of critically examining the theoretical foundations of LOD determination. We strongly recommend researchers to scrutinize the principles guiding LOD determination. The method proposed in this study offers an effective way to rigorously validate theoretical approaches for estimating LODs in gas concentration measurements using GC.


Assuntos
Limite de Detecção , Cromatografia Gasosa/métodos , Calibragem , Padrões de Referência , Técnicas de Diluição do Indicador
15.
Forensic Sci Int ; 357: 111992, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38518570

RESUMO

Substance misuse is a major problem among individuals involved in forensic-correctional mental health services. Urine drug screening detects substance use and deters the entry of contraband into forensic-correctional units, albeit with limitations. For example, a point-of-care urine sample may not be possible and patients can alter or substitute samples to avoid detection, highlighting the role of ancillary tools to detect contraband substances. This study describes the pattern and types of substances detected from environmental samples using a gas chromatographic analyzer (TeknoScan TSI3000) in forensic-correctional populations to model the benefits of similar tools in similar settings. Samples collected over 18 months (January 2020 to June 2021) by trained staff members using the machine were reviewed. During this period, 217 environmental samples were recorded, and 66 (30%) samples were positive for contraband substances, including tetrahydrocannabinol (25%), methamphetamines (19%), and cocaine (16%). Other substances detected include methylene-dioxymethamphetamine, heroin, morphine, lysergic acid diethylamide, tramadol, and methyl-benzoate. Fewer positive samples were detected, especially during the time corresponding with the COVID-19 restriction on the forensic units. TeknoScan was beneficial as an ancillary tool to detect and deter contraband substances. It also provided evidence for risk management. Adequate training is needed for the successful implementation of the tool.


Assuntos
Serviços de Saúde Mental , Transtornos Relacionados ao Uso de Substâncias , Humanos , Heroína , Morfina , Transtornos Relacionados ao Uso de Substâncias/diagnóstico , Cromatografia Gasosa
16.
J Chromatogr A ; 1721: 464823, 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38547679

RESUMO

This paper reports a method for determining the oil absorption value of inorganic powder based on tracer-assisted headspace gas chromatographic (HS-GC) technique. The method was carried out by adding 25 µL droplet of toluene-Dioctyl Phthalate solution onto the surface of 1.0 g inorganic powder, then sealing the headspace vial and shaking it to make the powder spherical. The amount of toluene that not been adsorbed by inorganic powder was quantified using HS-GC with the optimal equilibrium temperature and time conditions of 100 °C and 7 min, respectively. A new mathematical model shows that the oil absorption value can be determined from the signal of toluene. The results show that the employed method has good precision (the relative standard deviation < 3.6 %) and accuracy (R2 = 0.993). This method is simple and accurate, and can be an reliable tool for testing the oil absorption value of inorganic powder sample.


Assuntos
Tolueno , Pós , Cromatografia Gasosa/métodos , Temperatura , Tolueno/análise
17.
J Forensic Sci ; 69(3): 974-985, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38317608

RESUMO

Ethanol is the psychoactive substance identified most frequently in post-mortem specimens. Unfortunately, interpreting post-mortem ethanol concentrations can be difficult because of post-mortem alcohol redistribution and the possibility of post-mortem alcohol neogenesis. Indeed, in the time interval between death and sample collection, the decedent may be exposed to non-controlled environments for an extended period, promoting microbial colonization. Many authors report that in the presence of carbohydrates and other biomolecules, various species of bacteria, yeast, and fungi can synthesize ethanol and other volatile substances in vitro and in vivo. The aim of this study was to study the impact of several variables on microbial ethanol production as well as develop a mathematical model that could estimate the microbial-produced ethanol in correlation with the most significant consensual produced higher alcohol, 1-propanol. An experimental setup was developed using human blood samples and cadaveric fragments incubated under strictly anaerobic conditions to produce a novel substrate, "cadaveric putrefactive blood" mimicking post-mortem corpse conditions. The samples were analyzed daily for ethanol and 1-propanol using an HS-GC-FID validated method. The formation of ethanol was evaluated considering different parameters such as putrefactive stage, blood glucose concentration, storage temperature, and storage time. Statistical analysis was performed using the Mann-Whitney non-parametric test and simple linear regression. The results indicate that the early putrefactive stage, high blood glucose concentration, high temperature, and time of incubation increase microbial ethanol production. In addition, the developed mathematical equation confirms the feasibility of using 1-propanol as a marker of post-mortem ethanol production.


Assuntos
1-Propanol , Etanol , Mudanças Depois da Morte , Estudo de Prova de Conceito , Humanos , Etanol/análise , Manejo de Espécimes , Cromatografia Gasosa , Biomarcadores/análise , Biomarcadores/metabolismo , Depressores do Sistema Nervoso Central/análise , Toxicologia Forense , Concentração Alcoólica no Sangue , Cadáver , Temperatura , Modelos Teóricos , Ionização de Chama
18.
Talanta ; 271: 125728, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38316075

RESUMO

Carbohydrates, in particular the d-enantiomers of ribose, 2-deoxyribose, and glucose, are essential to life's informational biopolymers (RNA/DNA) and for supplying energy to living cells through glycolysis. Considered to be potential biosignatures in the search of past or present life, our capacity to detect and quantify these essential sugars is crucial for future space missions to the Moon, Mars or Titan as well as for sample-return missions. However, the enantioselective analysis of carbohydrates is challenging and both research and routine applications, are lacking efficient methods that combine highly sensitive and reproducible detection with baseline enantioselective resolution and reliable enantiomeric excess (ee) measurements. Here, we present four different derivatization strategies in combination with multidimensional gas chromatography coupled to a reflectron time-of-flight mass spectrometer (GC×GC-TOF-MS) for the enantioselective resolution of C3 to C6 carbohydrates potentially suitable for sample-return analyses. Full mass spectral interpretation and calibration curves for one single-step (cyclic boronate derivatives) and three two-step derivatization protocols (aldononitrile-acetate, hemiacetalization-trifluoroacetylation, and hemiacetalization-permethylation) are presented for concentrations ranging from 1 to 50 pmol µL⁻1 with correlation coefficients R2 > 0.94. We compared several analytical parameters including reproducibility, sensitivity (LOD and LOQ), overall separation, chiral resolution (RS), mass spectrum selectivity, stability during long term storage, and reliability of ee measurements to guide the application-dependent selection of optimal separation and quantification performance.


Assuntos
Glucose , Ribose , Reprodutibilidade dos Testes , Estereoisomerismo , Cromatografia Gasosa
19.
J Chromatogr A ; 1719: 464770, 2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38422708

RESUMO

A thermal desorber (TD) can be used in different ways to introduce samples in a gas chromatographic (GC) system. Besides its conventional use where the collected analytes are released from the sorbent in the sample tube, direct dynamic desorption (DDD) is an interesting option where a solid sample is put directly in the TD tube. However, since no sorbent is used for the sample, proper calibration is not straightforward. This issue was investigated in the present work using offline liquid calibration (OLC) and inline liquid calibration (ILC). Unexpectedly, ILC yielded a lower response than OLC. This could be related to the adsorption kinetics of the analytes and water on the cold trap of the TD. More insight was gained performing double injection ILC experiments with toluene as diluent for the analytes and injecting water before or after the toluene solution. This revealed a clear influence of the diluent. The influence of water was further explored applying two cold trap temperatures (4 °C and -30 °C). Inserting a LiCl trap in the TD tube to capture the water was found to be an effective solution for the problem. Finally, quantitative aspects of this approach were demonstrated.


Assuntos
Temperatura Baixa , Água , Calibragem , Cromatografia Gasosa/métodos , Água/química , Tolueno
20.
Planta Med ; 90(4): 316-332, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38387478

RESUMO

Concerns about health hazards associated with the consumption of trans-delta-8-tetrahydrocannabinol products were highlighted in public health advisories from the U. S. Food and Drug Administration and U. S. Centers for Disease Control and Prevention. Simple and rapid quantitative methods to determine trans-delta-8-tetrahydrocannabinol impurities are vital to analyze such products. In this study, a gas chromatography-flame ionization detection method was developed and validated for the determination of delta-8-tetrahydrocannabinol and some of its impurities (recently published) found in synthesized trans-delta-8-tetrahydrocannabinol raw material and included olivetol, cannabicitran, Δ 8-cis-iso-tetrahydrocannabinol, Δ 4-iso-tetrahydrocannabinol, iso-tetrahydrocannabifuran, cannabidiol, Δ 4,8-iso-tetrahydrocannabinol, Δ 8-iso-tetrahydrocannabinol, 4,8-epoxy-iso-tetrahydrocannabinol, trans-Δ 9-tetrahydrocannabinol, 8-hydroxy-iso-THC, 9α-hydroxyhexahydrocannabinol, and 9ß-hydroxyhexahydrocannabinol. Validation of the method was assessed according to the International Council for Harmonization guidelines and confirmed linearity with R2 ≥ 0.99 for all the target analytes. The limit of detection and limit of quantitation were 1.5 and 5 µg/mL, respectively, except for olivetol, which had a limit of detection of 3 µg/mL and a limit of quantitation of 10 µg/mL. Method precision was calculated as % relative standard deviation and the values were less than 8.4 and 9.9% for the intraday precision and inter-day precision, respectively. The accuracy ranged from 85 to 118%. The method was then applied to the analysis of 21 commercially marketed vaping products claiming to contain delta-8-tetrahydrocannabinol. The products analyzed by this method have various levels of these impurities, with all products far exceeding the 0.3% of trans-Δ 9-tetrahydrocannabinol limit for hemp under the Agriculture Improvement Act of 2018. The developed gas chromatography-flame ionization detection method can be an important tool for monitoring delta-8-tetrahydrocannabinol impurities in commercial products.


Assuntos
Dronabinol , Dronabinol/análogos & derivados , Resorcinóis , Vaping , Dronabinol/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos , Cromatografia Gasosa
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA